For cooling tower treatment applications, Genclean Disinfect is the solution for this application. Genclean Disinfect is fed into process water using a GWT chemical feed pump skid systems with integrated pH/ORP controllers which are capable of automatically adjusting dosage to maintain ORP in a typical range of +500mV to +700mV or higher based on water quality profile. This application guide range can be lab validated and field adjusted.
A suitable existing chemical feed system may also be used if it has this capability to automatically adjust dosage based on ORP values. This solution is mixed into the water using an inline static mixer or mechanical mixer.
Tertiary industrial process or wastewater treatment typically requires treatment process trains to reliable low maintenance treated water quality.
Genclean-Ind treatment solutions are fed into industrial wastewater using a GWT chemical feed pump system with an integrated pH/ORP controller to automatically proportionally adjust dosage to maintain oxidation reduction potential (ORP) in the range of +400mV to +750mV based on the application and water quality to control biofilm and fouling as well as the oxidation of certain contaminants. However, this application guide range can be lab validated and field adjusted based on industrial wastewater treatment goals.
A suitable existing chemical feed system may also be used if it has the capability to automatically adjust dosage rates in accordance with programmable ORP values. Genclean-Industrial can be effectively mixed into high flow rate tertiary industrial process water or wastewater applications using a suitable inline static mixer or mechanical mixing systems.
Drinking water disinfection requires effective treatment for both pathogens, emerging contaminants while providing residual disinfection without the generation of harmful byproducts in the presence of organic particles.
Genclean Muni treatment solution is fed into process water using a GWT chemical feed pump system with an integrated pH/ORP controller to automatically adjust dosage to maintain oxidation reduction potential (ORP) in the range of +700mV to +750mV at neutral pH values to provide suitable disinfection and oxidation of drinking water and domestic wastewater sources. This ORP range would be lab validated and can be field adjusted by trained utility staff to ensure proper and effective disinfection for health and safety.
A suitable existing chemical feed system may also be used if it has the capability for automatic adjustment of dosage rates based on ORP values. Genclean-Muni can be mixed into the drinking water or domestic wastewater application using a mechanical mixer or an inline static mixer for effective integration in the disinfection chamber or reactor tank.
The food processing and beverage processing industry requires effective disinfection from both pathogens such as bacterias like listeria and E-Coli.
Genclean AQ treatment solution is fed into process water or wastewater in food/beverage and fishery production operations using a GWT chemical feed pump system with an integrated pH/ORP controller to automatically proportionally adjust dosage to maintain oxidation reduction potential (ORP) in the range of typically at around +200 to +250 mV at neutral pH levels for aquaculture applications.
For food washing, ORP levels in the process wash water should be maintained at +675 to +725 mV with wash contact time of at least 30 seconds. The ORP ranges is this application guide can be lab validated and field adjusted to ensure proper and effective disinfection and oxidation.
A suitable existing chemical feed system may also be used if it has the capability for automatic adjustment of application dosage rates based on ORP values. Genclean-AQ can be mixed into the process water or wastewater application using a mechanical mixer or an inline static mixer for effective integration in the disinfection chamber or reactor tank. It can also be sprayed onto fruits, vegetables from spraying nozzle systems.
Resort/hotel pools, water parks and water features require suitable disinfection to handle algae & other microbiological contaminants effectively and efficiently.
The Genclean Pool treatment solution is introduced into the pool or water feature using a GWT automated chemical feed pump dosage system with integrated pH/ORP controller that would be installed with an inline mixer after the pool or water features water filtration system to provide maximum benefit with optimized capital and operational cost.
In dosing Genclean Pool, the integrated ORP controller on the GWT chemical feed system typically maintains ORP values at +700 mV minimum at neutral pH levels for optimal performance. The output values in this application guide programmed into the ORP/pH system controller shall be validated and monitored by trained staff to ensure proper and effective disinfection for health and safety.